DESCALING CHEMICALS
Purpose of chemical cleaning:The primary reasons for chemical cleaning of boilers/ heat exchangers are to prevent tube failures & improve unit availability. Tube failures in low pressure boilers/heat exchangers are normally the results of creep which occurs when internal deposits produce excessive metal temperature. A relatively smaller quantity of deposit creates difficulties in high pressure boilers. Caustic corrosion & hydrogen damage, which occur only in the presence of deposits, may cause tube failures at temperatures well below the creep limit. Deposits originating both from fabrication & during operation should be considered potential problems.
(
AFTER CLEANING )
After a boiler / heat exchanger placed into service, numerous solid constituents may enter the units with the feed water & some portion of the insolubles can be expected to deposit on surfaces. If not removed these deposits accumulated over a period of time can minimize the quantity of these materials; however, complete freedom from deposition is not possible in a high pressure system. The need for occasional chemical cleaning during the life of the equipment has become a recognized fact & should be accepted as a routine maintenance practice. A frequency of service cleaning of every 3 to 4 months is recommended. This frequency should be increased if individual unit operating history dictates.
DESCALING CHEMICAL
CHEMCON-1100 is designed to remove the
scaling& corrosion products from boiler& cooling water circuits, heat
changers etc. It is a liquid formulation to remove hardness & low
concentrated silica scales that can be removed offline by circulating its
dilute solution of the chemical. It is a balance formulation of
Hydrochloric Acid, Dispersant Wetting Agents & Corrosion Inhibitor
No comments:
Post a Comment